E4od high line pressure

E4od high line pressure. 36424-04K Line-to-Lube Pressure Regulator Valve Aug 23, 2012 · Some use it for a temperature sensor. Jun 15, 2016 · High line pressure Check pressures at line pressure tap. Highest quality spring material, designed to gently exceed OE The Sonnax Performance Pack HP-4R100-01 offers innovative, heavy-duty calibration for firmer shifts under load without sacrificing low-speed drivability. It also shows the various hydraulic circuits, electrical connections, and sensors that are integral to the transmission’s operation. Feb 24, 2016 · With transmissions, the computer will cause the internal tranny fluid line pressure to default to high to protect clutches and bands. $20. I think the maximum normal line pressure is about 100 PSI but I'm not 100% sure on that. 64. Takes about an hour, and fits all '89-01 diesel E4ODs. In the NEUTRAL position, line pressure is constantly applied to the right side of the accumulator piston, pushing it to the left. Apr 13, 2021 · Received 10 Likes on 10 Posts. Subscribed. OE Retaining Clip Sleeve OE Spring Plunger Valve O-Ring 1 OE Line Pressure Modulator Valve OEM Application OE Valve Diameter Sonnax Part No. This was supposed to support an increase in torque capacity at the clutch packs, but only had so much impact. 88K5 14b/d60 Self destruct mode switched to on! 97 Xcab Dodge crawler in the works. 1 / 1. capacity, 1/8-npt already tapped for trans temp gauge. Technicians are generally unsure of the cause, but replacement can help. So far I'm feeling pretty good cause I expected my worn out old E4OD to have low pressure. Durable, improved parts target commonly worn areas in the transmission to repair damage and prevent future wear Feb 7, 2017 · The average transmission pressure is between 90 and 130 psi where oil pressure is generally less than 60 psi, depending upon rpm. A final major difference is the oil pump. 1995 and up vehicles used either PWM or on-o TCC solenoid. You just need to get your line pressure up. in stock form, my e4od has a small section of rubber hose on the return line held on with hose clamps. No codes from the ecu, tried another ecu as well but same pressure. By studying the diagram, you can visually trace the flow of fluid Sep 28, 2017 · Some Ford E4OD, 4R100 transmissions have soft 1-2 or 2-3 shifts, intermittent harsh shifts or poor line rise complaints. 3. 3L Powerstroke. Details here at Bully Dog Shift Enhancer Kit for the GM Allison and Ford Power Stroke Transmission. Dec 18, 2023 · Transmission will shift through the rest of the gears smoothly and winds up at a little under 2500 RPM at 60mph in overdrive. 500" dia. Line Pressure Modulator Plunger Valve Kit 36948-05K Large 8-cylinder, . Jan 31, 2013 · Typically under high line pressure the trans will favor the internal fluid needs and restrict the outgoing flow. Now I drop it down to "R" which is supposed to be 75-99 PSI at idle, the Jan 23, 2021 · The rough shifting patterns can make it difficult to safely pilot your vehicle at low and high speeds. PART# 12345. It's VFS, which is Variable Force Solenoid. I am working on a 1995 F-250 4 wheel drive with 351 engine. What would cause excessive pressure in the pan and dipstick of an E40D trans? I have a 94 F-250, 5. $00. You can bring down gear hunting by adjusting the torque converter lock-up point and line pressure. These two (2) pin (wires) are the last two (2) wires on the outside of the connector toward the front of the truck. i bought. Views: 0. That way anything from the cooler is caught before entering the transmission. This high line pressure causes harsh upshift and engagements. The transmission was designed and built by Ford to fit a variety of their heavy-duty diesel vehicles such as the popular F-series trucks. Advantages: extra 3 qt. Sep 13, 2009 · It has the E4OD trans. This Technical Support section will help you fix problems that may arise with your transmission Ford E4OD, 4R100 transmissions often have problems with converter overheat, codes 62, 628, 1744, high line pressure and low cooler flow. It has a supercharged 351W. Reply. 427" Line Pressure Modulator Valve & Slee. The E4OD transmission diagram typically includes detailed illustrations of the internal components, such as the clutch plates, gears, and valves. Apr 20, 2024 · 1987 - 1996 F150 & Larger F-Series Trucks - E4OD Bellhoising Noise and Line Pressure - A little background: I have a 96 Bronco. Mag-Hytec high-capacity transmission pan. Just food for thought anyways. Contact Us. *96948-01K will recalibrate shift to Heavy Duty High Performance Feel. Pressure in the system corresponds to the car speed, operation parameters of the engine, engaged gear, etc. Note MLPS is located on driver's side of transmission case. If you don’t already have the 1995 and up OE replacements are hard to find, and many aftermarket springs have unacceptably high spring rates. Damage occurs to internal transmission parts, including warpage of metal parts, degradation of clutches, and melting of seals. Refer to Pressure Chart No. 0 or real low line pressure results in BANG shifts, as in "Limp Mode". Pump Body • E4OD Shown NOTE: Test ports on 4R100 slighlty different. Mar 7, 2014 · 94 E4OD fluid excessive pressure. 300° F=. MLPS adjustment Place manual lever in Neutral. The NEUTRAL-DRIVE (N-D) accumulator moderates a rapid increase in hydraulic pressure during forward clutch engagement. Valve, Sleeve, Line Pressure, Modulator, . 87. Sep 30, 2005 · The main line pressure regulator valve also controls the volume of oil that is fed to the torque converter: This, in turn, has a direct effect on converter release/fill pressure, cooling, lubrication and, in some cases, TCC apply pressure. It features an electronic shift control system and is designed for heavy-duty applications, making it ideal for towing and hauling. This reduces shift shock when the D range is selected from NEUTRAL. PWM. it has shifted hard since i got the truck, slams in all gears. Some E4OD, 4R100 transmissions have soft 1-2 or 2-3 shifts, intermittent harsh shifts or poor line rise complaints. OE replacements are hard to find, and many aftermarket springs have unacceptably high spring rates. 4r100 e4od ax4n 4f50n transmission line pressure modulator valve & sleeve kit . I have a 4r100 in a 1999 F250, 5. ) Dec 29, 2022 · Changing the line pressure modulator ratio to increase shift firmness is a very popular upgrade in Ford E4OD and 4R100 units. 00. : 0. To identify which you have look at the internal plastic solenoid cover: Black color is on-o and grey color is. Sep 5, 2017 · From the Baumann instructions The Quick 4 does not support the early ATR (MLPS or Range Sensor) connector used from 1989 to 1994. The accumulator control body is very Jan 1, 2013 · Sonnax Transmission Company 2 Imtec Lane, Bellows Falls, VT 05101-0440, USA. It is possible that with 4R100, E4OD Elevated Pressure Main Pressure Regulator Spring High line pressure; Low base line pressure you also need other 4R100 Some Ford E4OD, 4R100 transmissions have soft 1-2 or 2-3 shifts, intermittent harsh shifts or poor line rise complaints. The Sonnax elevated pressure main pressure regulator springs are intended to provide a minimal baseline pressure increase (approximately 10 psi over OE baseline pressure), enough of an increase to help restore full line pressure. Toggle menu (844) 298-6404 Jun 9, 2022 · I appreciate this reply. This results in no 4th in a 4R or no 2nd and 5th in the 5R unit. Tonight I attached my 0-120 psi oil pressure gauge to the pressure tap on my tranny. I have a trouble code 624 epc failure with engine misfire condition. Severe wear of the line pressure modulator sleeve allows EPC (electronic Feb 13, 2010 · Today I tried to check line pressure. Main Controls Bolts not tightened to specification Retighten bolts to specification. May 13, 2012 · No, it's not PWM. Jan 5, 2008 · Also sometimes it will not shift into 3rd gear. But using an online calculator (crawlpedia. While drilling the pump casting will allow full-time flow to the cooler circuit, it is not precise and allows converter drainback, causing delayed May 6, 2012 · I have a strange problem with my rebuilt 4l60e 1995, I have a constant line pressure of about 180psi in all gears including park and neutral. I was not able to match t Oct 12, 2020 · 175-200° F=. 155 subscribers. 54. i have a 92 f150 with a e40d. I was returning from a weekend trip when this occurred and had to drive about 150 miles in this condition. Pressure regulators are responsible for pressure retention within specified range. 11. a set off ebay that were listed for the transmission 95 E4OD valve body gaskets 1990-1995 36320EA,36321EA. Superior | E4OD (89-E93) Driver Adjustable Pressure Riser. It is possible that with 4R100, E4OD Elevated Pressure Main Pressure Regulator Spring High line pressure; Low base line pressure you also need other 4R100 The E4OD transmission features a four element torque converter design that includes Torque Converter Clutch (TCC) and a gear train that includes three planetary gearsets. 331" Feb 20, 2007 · At the time of inspection, we decided to add a bit of cooling insurance by installing TCI's High-Tech Racing Performance tranny cooler (PN 823800: $99. 1. Toggle menu (844) 298-6404 Description. Start engine and check line pressures. It's also the speedometer as it is attached to the rear of the speedo gauge. Heavy duty, high performance calibration kitPerformance Pack HP-4R100-014R100 only 36948-12 †, T36008A † Aggressive shifts Sep 28, 2017 · Some Ford E4OD and 4R100 transmissions have soft 1-2 or 2-3 shifts, intermittent harsh shifts or poor line rise complaints. 36948-03K. These can be caused by ECU (. Severe wear of the Line Pressure Modulator Sleeve allows EPC oil to leak past valve. Line Pressure Modulator Plunger Valve Kit 96948-01K Heavy duty/high performance, . 500" Diameter, E4OD, 4R100, Ford (89-UP) : Online Store 318-746-1568 | 877-406-0617 Transmission, Parts, Repair, Rebuild Oct 25, 2009 · EPC: electronic pressure control solenoid, located in the solenoid pack, controls shift firmness. Placeholder Product Name. 4L 4x4. Engine stall on engagement in Reverse, Oversized Line-to-Lube Pressure High line pressure 36424-04K F1, F5, F8 & E9 pump castings Regulator Valve Kit 36424-16K F1, F5, F8 & E9 pump castings F-36424-TL16C* Lockup shudder, TCC cycling TCC Control Plunger Valve Kit 36424-08K 4R100 PWM only Pressure Problems Soft shifts, Delayed Reverse, Low line rise 4R100 / E4OD Elevated Pressure Main Pressure Regulator Spring, Sonnax 36424-10. 372" 36948-05K Heavy Duty/High Performance or Stock AX4N ('97-Earlier) Replacement. The OE valve can close off critical converter/cooler circuit under high-demand situations, causing the TCC to drag on and glaze the lining at idle, or restricting converter/cooler charge during high load, leading to converter slip codes, overheat and lube Sep 28, 2017 · Some E4OD, 4R100 and AX4N transmissions have soft 1-2 or 2-3 shifts, intermittent harsh shifts or poor line rise complaints. i checked line pressure and they were all in spec. Connect pressure gauge to line pressure tap. This results in a very firm shift. (4. I had one in my business that the clutch was completely worn out in, once I got the line pressure up where it needed to be the trans NEVER had problems and I ran it like that for about 15K until I got a better truck. The truck is an old school district truck with 68,000 miles on it. Anyway, enought about the theory, here's the result. XDP carries all the parts and accessories you need for the best diesel performance. The trans pan has 20 bolts and I believe it to be an E40D. OD housing spiral lock snap ring. I got the following readings shifting through the gears: P - 120 psi R - 140+ psi D - 118 psi This Zip Kit services E4OD and 4R100 transmissions. May or may not set code 67/634 (MLPS out of position). 197k miles. 4R100 / AX4N / E4OD Line Pressure Modulator Plunger Valve Kit, Sonnax 96948-05K. Normal pan oil temperature operating range. No engine braking in D1, Burnt Low/Reverse Innovative line-to-lube components. as far as Valve body gaskets. Jun 16, 2018 · Sonnax now offers an upgraded line-to-lube pressure regulator valve 36424-04K with a patented internal line-to-lube passage with anti-drainback check valve, and a revised balance-end orifice. The E4OD transmission should automatically go into overdrive as the engine hits high RPMs. Add to Cart. it commanding 2nd but its physically in 1st with high rpm lift of accel pedal and it goes into 2nd. 427" 96948-01K Extreme Heavy Duty/High Performance . The truck has a plow and I don't know if the trans was ever rebuilt. Line up I. If the computer detects slippage in the transmission it will increase line pressure to maximum to try to stop the slip and protect the transmission. PSOM: programmable speedometer/odometer module. The transmission also turns off the shift solenoids to cause the unit to default to a single gear, usually second or third. I could only test in in the driveway running through the gears because the pressures were higher than 140 under acceleration. Maximum allowable oil pan temperature for short durations during long hill climbs. Could not find a special trans gauge but used one for oil pressure that goes to 140psi. It was found to not be adequately waterproof. Mar 19, 2019 · A Ford 4R100 / E4OD transmission controller can control this heavy duty automatic transmission made by the Ford Motor Company. High voltage does weird stuff to these modern trannys. D mark on sensor with l. Overdrive Malfunction. 2-3 shift valve. Understanding the various components of the E4OD transmission is important for troubleshooting and maintenance. A 4R100 Transmission. The transmission was intermittently having some codes about some shifts being too slow. It is common for E4OD/4R100 transmissions to have soft 1-2 or 2-3 shifts. 0000-0000 Placeholder Application. Here is the P/N for the Ford pan w/ the drain plug F81Z 7A194 BA. As far as numbers go, this is the info I got: Gear Range: @Idle Hot: @Stall Hot: Park or Neutral 55 - 70 psi N/A Pressure in the system corresponds to the car speed, operation parameters of the engine, engaged gear, etc. (All diesels are PWM after 1995 and most gas are on-o however some gas engine vehicles are also PWM thru 2001. Sep 30, 2005 · Ford E4OD, 4R100 transmissions often have problems with converter overheat, codes 62, 628, 1744, high line pressure and low cooler flow. Jul 24, 2014 · Check pressure at line pressure tap. Extreme heavy duty, . Apr 10, 2011 · 150, 1991, drive, e40d, e4od, fix, ford, line, low, main, pack, pressure, problems, solenoid, transmission. 372" dia. 8L, 4x4. . The powertrain control module will then operate the E4OD transmission at a higher line pressure to prevent transmission damage. If it sticks, the coast clutch will not apply. 700R4 Bearing Kit Kit Includes: 1- Stater to Input Drum Bearing 1- Input Drum to Sunshell Gear Bearing 1- Front Planet to Reaction Shaft Bearing 1- Rear Hub to Case Bearing 1- Rear Planet to Support Bearing. Severe wear of the line pressure modulator sleeve allows EPC (electronic pressure control) oil to leak past the valve and cause soft Aug 9, 2021 · High line pressure; Engine stumble on engagement in Reverse; Overheated converter; 4R100, E4OD Line Pressure Modulator Plunger Valve Kit 36948-03K. Ford services the old sensor by providing the new one with the updated connector shell and instructions for replacing it. Ford 4R100, AX4N, E4OD Line Pressure Modulator Plunger Valve Kit Part No. Some years ago, I had trouble with my E40D and decided to scrap it, go manual, and replace the ECU with a Microquirt which is much easier to tune than the stock SKU. Shifts and holds 1st and 2nd to any RPM when manually shifted, but retains automatic up shifts in drive Features: Gear Aug 13, 2020 · This test verifies the line pressure is within specifications. May 28, 2008 · Aight, I wanna increase my line pressure, and I'm thinking of doing the resistor mod. Severe wear of the line pressure modulator sleeve allows EPC (electronic pressure control ) oil to leak past the valve and cause soft shifts. Disadvantages: pricey @ $325 for E4OD (on a tight budget) 2. While there are many similarities and shared compo-nents between the E4OD and 4R100, significant diferences pertain to some components in this kit. Sonnax Transmission parts for Ford E4OD applications. Okiegringo Line pressure on the E4OD is critical and too much will quickly destroy it. O-Ring helps prevent EPC oil loss. For high pressure transmission fluid pumps, such as those used in racing applications, WIX recommends you use a high performance filter that will handle up to 200 psi, such as the WIX 51622 that I use. Our E4OD pressure lines are controlled by two (2) solenoids; a low ECP (Electronic Control Pressure) solenoid, which connects via pin 11 on the transmission connector; and a high ECP solenoid, via pin 12. It is known for its durability and ability to handle high torque applications. The 4R100: A deep dive at understanding and fixing problems. This can get VERY time consuming since ya gotta drain the fluid and drop the pan to make the adjustment. If line pressure is not within specifications, perform On-Board Diagnostics and Pinpoint Test E, air pressure check Some E4OD, 4R100 transmissions have soft 1-2 or 2-3 shifts, intermittent harsh shifts or poor line rise complaints. As it malfunctions, it may switch to neutral or 1995 and up E4OD and 98 and up 4R100 case connector. All too often however, the result is a transmission that shifts harder than expected. Main Regulator Valve • Code 62, 628, 1744 • Engine stall on engagement in Reverse • Engine stumble on engagement in Reverse • High line pressure • Overheated converter Replace with Sonnax Part Nos. When this bore is worn, the solenoid oil flows around it, resulting in the loss of overdrive servo release pressure. However, a fellow Oilburner suggested that the E4OD actually has two EPC solenoids, a low and a high pressure one, and that the white/yellow wire (runs off pin #11 at the plug) is the one for the low pressure solenoid. These can be caused by ECU (electronic control unit) or accumulator pressure problems. 77fj40/94fzj80 The E4OD transmission, also known as the Electronic 4-speed Overdrive, is a four-speed automatic transmission used in Ford vehicles. Shop On Our Website For More 4R100 Products Today! Call Us At 318-742-7353! Jan 5, 2008 · I have a Ford F series Pickup equipped with the E4OD. Precision components upgrade the 4R100 for maximum performance and durability by recalibrating pressures and shift accumulation. This is a departure from the 'constantly variable' line pressure provided by the EPC solendoid/PCM,ECC. I assume something is wrong inside Ford E4OD, 4R100 transmissions often have problems with converter overheat, codes 62, 628, 1744, high line pressure and low cooler flow. Sean Velez. Both these transmissions are electronically controlled 4 Some E4OD, 4R100 transmissions have soft 1-2 or 2-3 shifts, intermittent harsh shifts or poor line rise complaints. It shifts real nice, just late. 96) and a "Max-Cool" diesel aluminum fluid Mar 16, 2006 · Mar 21, 2006 #4. The 4R100 transmission oil pump was designed to produce line pressure faster and more efficiently than the original E40D transmission could. Jun 4, 2010 · 1995 E4OD no line pressure increse w/load. 6-Cylinder & Small 8-Cylinder Applications . 500″ dia. Advantages: only $70, but I would probably still need a high capacity pan for extra cooling. If high, check the following possible components: main controls, filter assembly and seal. Only item that may affect both situations is if the trucks' electrical system is operating at a high voltage IE: 15+ volts. Your first step should be to scan the computer for trouble codes. Dec 16, 2008 · It's a kit with three springs, a valve, and a drill bit to increase the size of the transmission fluid feed lines for increased shift pressure and reduced torque converter slippage. 96948-01K • Plunger Valve • Sleeve • O-Ring NOTE: For use in heavy duty/high performance or stock AX4N ('97-earlier) replacement applications. 10 rear and factory sized 30” rubber gives me 1929 rpm. B&M super cooler. 2. 401 for specifications. The OE valve can close off critical converter/cooler circuit under high-demand situations, causing the TCC to drag on and glaze the lining at idle, or restricting converter/cooler charge during high load, leading to converter slip codes, overheat and lube Jan 18, 2006 · 1. The pressure does not change when I rev the engine. Well, the temps seem to run in the 180° range going down the road yet when I get into a pull in our local mountains, the temps can rise up into the yellow area in the 220 98 - 03 E4OD/4R100 . If pressures are high or all shifts are harsh, go to main controls. 427" by sonnax fits '89+ ford Rating Required Select Rating 1 star (worst) 2 stars 3 stars (average) 4 stars 5 stars (best) Sep 21, 2005 · The CCS is not modulated, but controlled as an on-and-off valve by the SSD/CCS solenoid. i scaned for codes and there was none. Buy in monthly payments with Affirm on orders over $50. The slight increase in spring pressure compensates for wear elsewhere in the transmission. Feb 28, 2006 · So, to firm up ONLY slipping this device must alter the line pressure. com) at 60 mph in OD with my 4. External transmission filter kit. Line Pressure Test P) 90 Dec 19, 2006 · E4OD oil pressure too high. 800-843-2600 · 802-463-9722. Choosing the right Sonnax kit for your application is key to achieving the shift feel you want. mark on plastic bushing So no line pressure at the test port would suggest a pump issue to me. Jan 23, 2007 · Here is info on how to raise the line pressure, but be sure to put a gauge on the line and make VERY small adjustments. i rebuilt me e40d new clutches put in a shift kit the modified the pump and new springs in the E4OD/4R100 transmissions often have problems with converter overheat, codes 62, 628, 1744, high line pressure and low cooler. Clutch, Transmission, Differential, Axle & Transfer Case - e40d with low line pressure help!!!! - well here's the story. Reverse was smoked bad!!! Got it all back together and on test drive the 1-2 shift is real late to me around 30 mph under very light throttle it goes into second. The Driver Adjustable PressureRiser is a control module that is mounted inside the vehicle allowing the driver to switch "on the fly" from no modification to Standard, Heavy Duty, or High Performance. Some Ford E4OD and 4R100 transmissions have soft 1-2 or 2-3 shifts, intermittent harsh shifts or poor line rise complaints. $18. See application chart and technical information below. Severe wear of the line pressure modulator sleeve allows EPC (electronic pressure control) oil to leak past the valve and cause soft shifts. 275° F=. Oct 7, 2007 · In my experience an E4OD will work fine with a bad converter clutch. The hydraulic control systems of the E4OD transmission has five electronically controlled solenoids for: Shift feel (through line pressure control), Shift The line pressure should reach its maximum rate (180-280 psi, depending upon valve body calibration. Started it up, oil pressure reads 60 PSI, spec is 55-65 PSI at idle. When your shifts slam does the OD light flash? That would indicate that a code is stored, When the PCM stores a transmission code it sets pressure high to help prevent transmission damage. Jan 15, 2007 · IF the line pressure goes high with the Shaffer shifter on it, chances are you have a hydraulic problem , not electronic / computer control. Coast clutch HD snap ring. My ‘92 van doesn’t have a tach. May 25, 2020 · 1990 Ford E4OD - - Line Pressure Test - Troubleshooting only second gear Issue - unedited. Shop ATS Built E4OD Transmission Package for the 1994-1997 Ford 7. ) If line pressure is low in either of these tests, then the problem is in the transmission and not related to the controller or its calibration. High temp direct clutch seal. 331" 36948-03K Large 8-Cylinder Applications . Low line rise, Low EPC pressure Line Pressure Modulator Plunger Valve Kit 36948-03K 6- & Small 8-cylinder, . Monster Sale Price: 91. At times my overdrive light flashes and the transmission shifts very hard, what could cause this? The flashing OD light is an indication of a transmission related trouble code in the Powertrain Control Module (PCM). Line pressure is inversely proportional to the FIPL voltage. 1K views 3 years ago. The E4OD transmission is a four-speed automatic overdrive transmission used in Ford trucks from 1989 to 1997. Step 2: Pull codes! Here is a writeup on how to pull codes: Ford Fuel Injection How To Run a Self-Test. Here are what the codes mean. I also had intermittent scraping sounds from, what I now understand was probably the torque converter. Condition: New. With its robust design, it can handle high torque loads while maintaining smooth shifting and efficiency Sep 29, 2004 · Can cause wrong gear starts, no upshift, falls out of gear, and high line pressure = harsh upshift and engagements. 401 for specification. Perform Line Pressure and Stall Speed Tests. 10 rear) This seems off to me. 331" dia. Oct 11, 2006 · The initial result is a +/-20 psi boost in line pressure, followed by a perfectly linear increase in line pressure with respect to RPM's. Refer to the following chart to determine if line pressure is within specification. Dia. Line Pressure Modulator Plunger Valve Kit 96948-05KExtreme heavy duty, . 427" dia. so i droped it off at a trans shop today and just got the call, they said it was a bad pressure regulator and needed a whole rebuild. I've never measured the pressure in the line returning from the coolers, but there is less than 30 PSI going to the coolers, so it's definitely less than 30 PSI. Not a lot. All gears work fine, overdrive and lockup too. D. Decent pressure at the port with no movement in any gear would point to internal converter failure of some sort. The pressure is inversely proportional to current. When it has a trouble code related to the transmission it usually commands full line pressure to try to protect the Sep 28, 2017 · Sonnax line pressure modulator plunger valve kit 36948-03K eliminates this oil loss problem in listed units. Be the first to review this product. On 92 and up it converts the rear ABS signal into a VSS signal for the trans. Updated direct clutch outer seal, Calibration plate for firmness adjustments. 500" 96948-05K Figure 1 Nov 22, 2009 · Ford offers a pan with a drain plug and you can search for writeups on drain plug installation. 36424-10A E4OD 4R100 Transmission main pressure regulator spring (1 spring) The Sonnax elevated pressure main pressure regulator springs are designed to provide an effective baseline pressure. Model: 96948-01K. Superior | PR210 E40D Pressure Riser Package. Monster Sale Price: 32. Auxiliary filters are generally put on the return line from the cooler. If it also changes shift points, like the Baumann TCS, it must alter the FIPL voltage from the OEM computer. Aug 31, 2022 · The E4OD is an electronically-controlled gear system requiring reprogramming to minimize gear hunting and boost operation. Oct 15, 2002 · Clutch, Transmission, Differential, Axle & Transfer Case - e4od line pressure - i currently swaped the rear axle out of an 85 f-150 into a 94 f-150, little did i know that the 94 contained a prox sensor for the psom. Gaskets damaged Inspect for damage and May 23, 2017 · Thank you again for all your help. Learn more. In controlling converter feed, the PR valve is a type of priority valve. Sonnax 36424-04K E4OD Line to lube pressure regulator valve E4OD 4R100 transmission parts Feb 3, 2018 · If a malfunction occurs in the AP sensor circuit, the powertrain control module will recognize that the AP sensor signal is out of specification. 1987 - 1996 F150 & Larger F-Series Trucks - Code 624, 97 f53 e4od - Hello all, looking for some help. Dec 29, 2012 · I was told that continuous high-temps generally only affect clutch pack linings and O-rings, --and higher convertor temps are normal when the convertor is not locked-up. Some E4OD, 4R100 and AX4N transmissions have soft 1-2 or 2-3 shifts, intermittent harsh shifts or poor line rise complaints. mk sh rj jr yc qj bo db gv qg